Uninterruptible power supply system for home with stabilization 0.8kW | 2.7kW | 6 kW | 10 kW

All solutions

0.8kW UPS (for a gas boiler)

from 350 000 KZT

Set contents:

Power

0,8 kW;

USP type

ON-LINE;

Number of phases

Single-phase;

Voltage stabilization

Yes;

Number of external batteries

x 2;

Capacity per battery

33|55|100|200 Ah;

Battery technology

AGM;

Battery rack

Optional;

Run time (10% continuous load)

from 7h;

Run time (50% continuous load)

from 7h;

2.7kW UPS

from 800 000 KZT

Set contents:

Power

2,7 kW;

USP type

ON-LINE;

Number of phases

Single-phase;

Voltage stabilization

Yes;

Number of external batteries

x 6;

Capacity per battery

55-100 Ah;

Battery technology

AGM;

Battery rack

Optional;

Run time (10% continuous load)

from 10h;

Run time (50% continuous load)

from 2h;

6kW UPS

from 1 400 000 KZT

Set contents:

Power

6 kW;

USP type

ON-LINE;

Number of phases

Single-phase;

Voltage stabilization

Yes;

Number of external batteries

x 16;

Capacity per battery

33|45 Ah;

Battery technology

AGM;

Battery rack

Optional;

Run time (10% continuous load)

from 7,4h;

Run time (50% continuous load)

from 1,5h;

10kW UPS

from 2 300 000 KZT

Set contents:

Power

10 kW;

USP type

ON-LINE;

Number of phases

Single-phase;

Voltage stabilization

Yes;

Number of external batteries

x 16;

Capacity per battery

55|65 Ah;

Battery technology

AGM;

Battery rack

Optional;

Run time (10% continuous load)

from 7,5h;

Run time (50% continuous load)

from 1,5h;

A popular and reliable guaranteed clean power supply system for home.

In this solution, an on-line uninterruptible power supply (UPS), which operates like a voltage stabilizer, is used instead of an inverter

There are several the most common issues with power supply, which are solved with the help of a UPS. This is one of the major benefits. These issues include:

  • Voltage losses, falls, spikes.
  • Reduced or increased voltage.
  • Frequency deviation.
  • Nonlinear voltage distortions.
  • Transient processes when switching.
  • Interference of radio frequency and electromagnetic origin

Used to power the entire house or part of it. In the latter case, priority equipment is chosen from all the equipment necessary for the life support of the house. Such as:

  • a gas boiler and circulation pumps;
  • water supply system;
  • a refrigerator;
  • common areas lightening;
  • intercom, Internet and CCTV;
  • automatic gates.

A standard set of equipment consists of:

  • a UPS;
  • batteries;
  • a battery rack.

The UPS power and the capacity of the batteries are selected individually for the needs of the customer.

Standard connection diagram

A connection diagram for an uninterruptible power supply (UPS) with external batteries

Submit a request